Login

Email   Password
  
 

Why Join ASHRAE

ASHRAE Membership

ASHRAE membership is open to any person associated with heating, ventilation, air conditioning or refrigeration. ASHRAE is unique because its membership is drawn from a wide range of disciplines relating to the HVAC&R field. Approximately 51,000 individuals from more than 100 nations belong to the Society.

Discounts on Publications

ASHRAE members earn 15% off publications. Hundreds of titles are available including the complete collection of ASHRAE Standards including 90.1, 62.1 and 189.1.
Click here for information on joining or to join ASHRAE

Develop Leadership Skills

When you join ASHRAE, you are making an investment in yourself. When you become active in the Society by giving your time and sharing your knowledge, you get even more out of that investment.

Network with Industry Professionals

Each month, all over the world, ASHRAE chapters convene for an informational program featuring a speaker or topic that is key to professionals in the industry. Meet with your peers and share ideas.
 
 
Need technical info? Search ASHRAE's Bookstore >
 
 
Resources & Publications
 

0913-Standards

Standards Actions - September 2013

All standards activities are announced and published on ASHRAE.org. Information about call for members, call for comments, errata, publications, new projects, addenda availability and interpretations can be found at www.ashrae.org/publicreviews.

Until Oct. 6, 2013

  • Addenda k, q, r and s to Standard 62.1-2010, Ventilation for Acceptable Indoor Air Quality
  • Addenda a and b to Standard 62.2-2013, Ventilation and Acceptable indoor Air Quality in Low-Rise Residential Buildings
  • Addendum ad to Standard 170-2008, Ventilation of Health Care Facilities
  • Addenda v, aq, at, au and av to Standard 189.1-2011, Standard for the Design of High Performance Buildings Except Low-Rise Residential Buildings

Until Oct. 21, 2013

  • Addenda as to Standard 189.1-2011, Standard for the Design of High Performance Buildings Except Low-Rise Residential Buildings

Until Oct. 7, 2013

  • Addendum a to Standard 52.2-2012, Method of Testing General Ventilation Air Cleaning Devices for Removal Efficiency by Particle Size
  • Addendum ae to Standard 170-2008, Ventilation of Health Care Facilities
  • Addendum a to 206-2013, Method of Test for Rating of Multi-Purpose Heat Pumps for Residential Space Conditioning and Water Heating

Until Sept. 22, 2013

  • Addendum a to Guideline 28-2012, Air Quality Within Commercial Aircraft
  • Addendum b to Standard 206-2013, Method of Test for Rating of Multi-Purpose Heat Pumps for Residential Space Conditioning and Water Heating

Until Sept. 16, 2013

  • Addendum an to Standard 135-2012, BACnet – A Data Communications Protocol for Building Automation and Control Networks
  • Addendum o to Standard 135.1-2011, Method of Test for Conformance to BACnet
  • Standard 22-2007(R), Methods of Testing for Rating Liquid Cooled Refrigerant Condensers

Publication Withdrawal

  • Addendum cx to Standard 90.1-2010, Energy Standard for Buildings Except Low-Rise Residential Buildings

Publication Notice

  • Guideline 33-2013, Guideline for Documenting Indoor Airflow and Contaminant Transport Modeling
  • Standard 41.10-2013, Standard Methods for Volatile Refrigerant Mass Flow Measurement Using Flowmeters
  • Standard 182-2008 (RA 2013), Method of Testing Absorption Water-Chilling and Water-Heating Packages
  • Standard 195-2013, Method of Test for Rating Air Terminal Unit Controls
  • Standard 202-2013, Commissioning Process for Buildings and Systems
  • Standard 206-2013, Method of Testing for Rating of Multi-Purpose Heat Pumps for Residential Space Conditioning and Water Heating
  • Addenda g, h and I to Guideline 13-2007, Specifying Direct Digital Control Systems
  • Addenda w, x, ag, ah, ai, aj and ak to Standard 34-2010, Designation and Safety Classification of Refrigerants
  • Addenda i, k, l, m, n, o, p, q and r to Standard 55, Thermal Environmental Conditions for Human Occupancy
  • Addendum m to Standard 84-2013, Method of Testing Air-to-Air Heat/Energy Exchangers
  • Addendum g to Standard 161-2007, Air Quality within Commercial Aircraft
  • Addenda u, w, x, z and ab to Standard 170-2008, Ventilation of Health Care Facilities

Interpretations

  • Standard 62.2-2013, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, 62.2-2013-1
  • Standard 190-2013, Method of Testing for Rating Indoor Pool Dehumidifiers, 190-2013-1
  • Standard 170-2008, Ventilation of Health Care Facilities, 170-2008-6
  • Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings Except Low-Rise Residential Buildings, 189.1-2011-1

Meetings

  • SSPC 55, Thermal Environmental Conditions for Human Occupancy, Sept. 9, Oct. 7, Nov. 4, Dec. 2 and Jan. 6
  • SSPC 15, Safety Standard for Refrigeration Systems, Oct. 8
  • SSPC 62.2-2013, Ventilation and Acceptable indoor Air Quality in Low-Rise Residential Buildings, Sept. 18
  • SPC 105-2007R, Standard Methods of Measuring and Expressing Building Energy Performance, Oct. 3
  • SPC 188P, Prevention of Legionellosis Associated with Building Water Systems, Nov. 15
  • SSPC 189.1-2011, Standard for the Design of High Performance Buildings Except Low-Rise Residential Buildings, Sept. 24, Oct. 29, Nov. 26, Dec. 19, Jan. 7, Feb. 25, March 25 and April 29