Numeric Index

Share This

II. Numeric Index with Titles (August 2016)

Standard or Guideline
Project Committee
Title
Gdl 0-2013 SSPC 202 The Commissioning Process
Gdl 0.2-2015 GPC 1.2 The Commissioning Process for Existing Systems and Assemblies
Gdl 1.1-2007 (Formerly Gdl 1-1996)   HVAC&R Technical Requirements for the HVAC Commissioning Process
Gdl 1.1-2007R SSPC 202 HVAC&R Technical Requirements for the HVAC Commissioning Process
  GPC 1.2P (Formerly GPC 30P) The Commissioning Process for Existing HVAC&R Systems
  GPC 1.3P (Formerly GPC 31P) Building Operation and Maintenance Training for the HVAC&R Commissioning Process
Gdl 1.4-2014 Systems Manual Preparation for the Commissioning Process.
Gdl 1.5-2012 (Formerly Gdl 5-1994)   The Commissioning Process for Smoke Control Systems
Gdl 1.5-2012R SSPC 202 The Commissioning Process for Smoke Control Systems
Gdl 2-2010 (RA 2014)   Engineering Analysis of Experimental Data
Gdl 4-2008 (RA 2013)   Preparation of Operating and Maintenance Documentation for Building Systems
Gdl 4-2008R GPC 4 Preparation of Operating and Maintenance Documentation for Building Systems
Gdl 6-2015 Refrigerant Information Recommended for Product Development and Standards
Gdl 10-2011 SGPC 10 Interactions Affecting the Achievement of Acceptable Indoor Environments
Gdl 11-2009 Field Testing of HVAC Controls Components
Gdl 11-2009R GPC 11 Field Testing of HVAC Controls Components
Gdl 12-2000 SSPC 188 Minimizing the Risk of Legionellosis Associated With Building Water Systems
Gdl 13-2015 SGPC 13 Specifying Building Automation Systems
Gdl 14-2014 Measurement of Energy and Demand Savings
Gdl 16-2014   Selecting Outdoor, Return, and Relief Dampers for Air-Side Economizer Systems
Gdl 20-2010 (RA 2016) Documenting HVAC&R Work Processes and Data Exchange Requirements
Gdl 21-2012   Guideline for Stationary Battery Room Ventilation and Thermal Conditions
Gdl 21-2012R GPC 21 Guideline for Stationary Battery Room Ventilation and Thermal Conditions
Gdl 22-2012   Instrumentation for Monitoring Central Chilled Plant Efficiency
Gdl 22-2012R GPC 22 Instrumentation for Monitoring Central Chilled Plant Efficiency
  GPC 23P Guideline for the Design and Application of Heating, Ventilation and Air Conditioning Equipment for Rail Passenger Vehicles
Gdl 24-2015  SSPC 62.2 Ventilation and Indoor Air Quality In Low-Rise Residential Buildings
  GPC 25P (Replace Std 74-1988) Method of Measuring Solar-Optical Properties of Materials
Gdl 26-2012   Guideline for Field Testing of General Ventilation Filtration Devices and Systems for Removal Efficiency In-Situ by Particle Size and Resistance to Airflow
  GPC 27P Measurement Procedures for Gaseous Contaminants in Commercial Buildings
Gdl 28-2016  SSPC 161 Air Quality Within Commercial Aircraft
Gdl 29-2009   Guideline for Risk Management of Public Health and Safety in Buildings
Gdl 29-2009R GPC 29 Guideline for Risk Management of Public Health and Safety in Buildings
Gdl 32-2012   Sustainable, High Performance Operations & Maintenance
Gdl 32-2012R GPC 32 Sustainable, High Performance Operations & Maintenance
Gdl 33-2013   Guideline for Documenting Indoor Airflow and Contaminant Transport Modeling
  GPC 34P Energy Guideline for Historical Buildings and Structures
  GPC 35P Method for Determining the Energy Consumption Caused By Air-Cleaning and Filtration Devices 
  GPC 36P High Performance Sequences of Operation for HVAC Systems
  GPC 37P Guidelines for the Application of Upper-Air (Upper Room) Ultraviolet Germicidal (UV-C) Devices to Control the Transmission of Airborne Pathogens
  GPC 38P (Replace Std 175P) Guideline for Using Metal Pressure Vessels to Test Materials Used in Refrigeration Systems
  GPC 39P (Replace Std 177P) Method of Test for Measuring Fractionated Compositions of Refrigerant Blends
  GPC 40P (Replace Std 99-2006R) Refrigeration Oil Description
  GPC 41P Design, Installation and Commissioning of Variable Refrigerant Flow Systems
  Gdl 42P
SSPC 62.1
Indoor Air Quality in Commercial and Institutional Buildings
Std 15-2013 SSPC 15 Safety Standard for Refrigeration Systems (Supersedes ANSI B9.1, Safety Code for Mechanical Refrigeration) and Addenda
Std 16-1983 (RA 2014) Method of Testing for Rating Room Air Conditioners and Packaged Terminal Air Conditioners
Std 16-1983R SPC 16 Method of Testing for Rating Room Air Conditioners and Packaged Terminal Air Conditioners
Std 17-2015 Method of Testing Capacity of Thermostatic Refrigerant Expansion Valves
Std 18-2008 (RA 2013)   Methods of Testing for Rating Drinking-Water Coolers with Self-Contained Mechanical Refrigeration
Std 20-1997 (RA 2016) Methods of Testing for Rating Remote Mechanical-Draft Air-Cooled Refrigerant Condensers
Std 20-1997R SPC 20 Methods of Testing for Rating Remote Mechanical-Draft Air-Cooled Refrigerant Condensers
Std 22-2014   Methods of Testing for Rating Liquid-Cooled Refrigerant Condensers
Std 23.1-2010   (Formerly Std 23-2005) Methods of Testing for Performance Rating Positive Displacement Refrigerant Compressors and Condensing Units That Operate at Subcritical Temperatures of the Refrigerant 
Std 23.1-2010R SPC 23.1 Methods of Testing for Performance Rating Positive Displacement Refrigerant Compressors and Condensing Units That Operate at Subcritical Temperatures of the Refrigerant 
 Std 23.2-2014 Method of Test for Rating the Performance of Positive Displacement Compressors that Operate at Supercritical Pressures of the Refrigerants(formerly SPC 186P)
Std 24-2013   Methods of Testing for Rating Liquid Coolers
Std 24-2013R SPC 24 Methods of Testing for Rating Liquid Coolers
Std 25-2001 (RA 2016) Methods of Testing Forced Convection and Natural Convection Air Coolers for Refrigeration
Std 25-2001R SPC 25 Methods of Testing Forced Convection and Natural Convection Air Coolers for Refrigeration
Std 26-2010 Mechanical Refrigeration and Air Conditioning Installations Aboard Ship
Std 26-2010R SPC 26 Mechanical Refrigeration and Air Conditioning Installations Aboard Ship
Std 28-1996 (RA 2010) Method of Testing Flow Capacity of Refrigerant Capillary Tubes
Std 28-1996R SPC 28 Method of Testing Flow Capacity of Refrigerant Capillary Tubes
Std 29-2015 Methods of Testing Automatic Ice Makers
Std 30-1995 Methods of Testing Liquid Chilling Packages
Std 30-1995R SPC 30 Methods of Testing Liquid Chilling Packages
Std 32.1-2010 Methods of Testing for Rating Vending Machines for Sealed Beverages
Std 32.1-2010R SPC 32.1 Methods of Testing for Rating Vending Machines for Sealed Beverages
Std 32.2-2003 (RA 2011)   Methods of Testing for Rating Pre-Mix and Post-Mix Beverage Dispensing Equipment
Std 32.2-2003R SPC 32.2 Methods of Testing for Rating Pre-Mix and Post-Mix Beverage Dispensing Equipment
Std 33-2016 Methods of Testing Forced Circulation Air Cooling and Air Heating Coils
Std 34-2013 SSPC 34 Designation and Safety Classification of Refrigerants
Std 35-2014   Method of Testing Desiccants for Refrigerant Drying
Std 37-2009 Methods of Testing for Rating Electrically Driven Unitary Air-Conditioning and Heat Pump Equipment
Std 37-2009R SPC 37 Methods of Testing for Rating Electrically Driven Unitary Air-Conditioning and Heat Pump Equipment
Std 40-2014   Methods of Testing for Rating Heat Operated Unitary Air Conditioning and Heat-Pump Equipment
Std 41.1-2013 Standard Methods for Temperature Measurement
Std 41.1-2013R   Standard Methods for Temperature Measurement
Std 41.2-1987 (RA 1992) Standard Methods for Air Velocity and Airflow Measurement
Std 41.2-1987R SSPC 41 Standard Methods for Air Velocity and Airflow Measurement
Std 41.3-2014 Standard Methods for Pressure Measurement
Std 41.4-2015 Standard Methods for Proportion of Lubricant in Liquid Refrigerant Measurement
Std 41.6-2014 Standard Method for Measurement of Moist Air Properties
Std 41.7-2015 Method of Test for Measurement of Flow of Gas
Std 41.8-2016 Standard Methods of Measurement of Flow of Liquids in Pipes Using Orifice Flowmeters
Std 41.9-2011 Standard Methods for Volatile-Refrigerant Mass Flow Measurements Using Calorimeters
Std 41.9-2011R SSPC 41 Standard Methods for Volatile-Refrigerant Mass Flow Measurements Using Calorimeters
Std 41.10-2013 Standard Methods for Volatile Refrigerant Mass Flow Measurement Using Flowmeters (Previously 20%P)
Std 41.10-2013R SSPC 41 Standard Methods for Volatile Refrigerant Mass Flow Measurement Using Flowmeters (Previously 20%P)
Std 41.11-2014 Standard Methods for Power Measurement 
Std 51-2007 Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (AMCA 210-07) (AMCA is the lead organization for this standard)
Std 51-2007R SPC 51 Laboratory Methods of Testing Fans for Aerodynamic Performance Rating (AMCA 210-07) (AMCA is the lead organization for this standard)
Std 52.2-2012 SSPC 52.2 Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size
Std 55-2013 SSPC 55 Thermal Environmental Conditions for Human Occupancy
Std 59-1986 (RA 2014) Method of Testing for Rating Room Air Conditioner and Packaged Terminal Air Conditioner Heating Capacity
Std 58-1986R SPC 58 Method of Testing for Rating Room Air Conditioner and Packaged Terminal Air Conditioner Heating Capacity
Std 62.1-2016 SSPC 62.1 Ventilation for Acceptable Indoor Air Quality
Std 62.2-2016 SSPC 62.2 Ventilation and Acceptable Indoor Air Quality in Residential Buildings
Std 63.1-1995 (RA 2001) Method of Testing Liquid Line Refrigerant Driers
Std 63.1-1995R SPC 63.1 Method of Testing Liquid Line Refrigerant Driers
Std 63.2-1996 (RA 2010) Method of Testing Liquid-Line Filter Drier Filtration Capability
Std 63.2-1996R SPC 63.2 Method of Testing Liquid-Line Filter Drier Filtration Capability
Std 64-2011   Methods of Laboratory Testing Remote Mechanical-Draft Evaporative Refrigerant Condensers
Std 64-2011R SPC 64 Methods of Laboratory Testing Remote Mechanical-Draft Evaporative Refrigerant Condensers
Std 70-2006 (RA 2011) Method of Testing for Rating the Performance of Air Outlets and Air Inlets
Std 70-2006R SPC 70 Method of Testing for Rating the Performance of Air Outlets and Air Inlets
Std 72-2014 SSPC 72 Method of Testing Open Refrigerators
Std 78-1985 (RA 2007) Method of Testing Flow Capacity of Suction Line Filters and Filter-Driers
Std 78-1985R SPC 78 Method of Testing Flow Capacity of Suction Line Filters and Filter-Driers
Std 79-2015 Methods of Testing for Rating Room Fan-Coil Conditioners
Std 84-2013   Method of Testing Air-to-Air Heat Exchangers
Std 84-2013R SPC 84 Method of Testing Air-to-Air Heat Exchangers
Std 86-2013   Methods of Testing the Floc Point of Refrigeration Grade Oils
Std 90.1-2013 SSPC 90.1 Energy Standard for Buildings Except Low-Rise Residential Buildings
Std 90.2-2007 Energy Efficient Design of Low-Rise Residential Buildings
Std 90.2-2007R SSPC 90.2 Energy Efficient Design of Low-Rise Residential Buildings
 Std 90.4-2016 Energy Standard for Data Centers and Telecommunications Buildings
Std 93-2010 (RA 2014)   Methods of Testing to Determine the Thermal Performance of Solar Collectors
Std 94.2-2010 Method of Testing Thermal Storage Devices with Electrical Input and Thermal Output Based on Thermal Performance
Std 94.2-2010R SPC 94.2 Method of Testing Thermal Storage Devices with Electrical Input and Thermal Output Based on Thermal Performance
Std 97-2007 Sealed Glass Tube Method to Test the Chemical Stability of Materials for Use Within Refrigerant Systems
Std 97-2007R SPC 97 Sealed Glass Tube Method to Test the Chemical Stability of Materials for Use Within Refrigerant Systems
Std 99-2006 Refrigeration Oil Description
Std 100-2015 SSPC 100 Energy Conservation in Existing Buildings
Std 103-2007 Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers
Std 103-2007R SPC 103 Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers
Std 105-2014   Standard Methods of Measuring, Expressing, and Comparing Building Energy Performance
Std 110-2016 Method of Testing Performance of Laboratory Fume Hoods
Std 111-2008 Measurement, Testing, Adjusting and Balancing of Building Heating, Ventilation and Air-Conditioning Systems
Std 111-2008R SPC 111 Measurement, Testing, Adjusting and Balancing of Building Heating, Ventilation and Air-Conditioning Systems
Std 113-2013   Method of Testing for Room Air Diffusion
Std 113-2013R SPC 113 Method of Testing for Room Air Diffusion
Std 116-2010   Methods of Testing for Rating Seasonal Efficiency of Unitary Air Conditioners and Heat Pumps
Std 118.1-2012   Method of Testing for Rating Commercial Gas, Electric, and Oil Service Water Heating Equipment
Std 118.1-2012R SPC 118.1 Method of Testing for Rating Commercial Gas, Electric, and Oil Service Water Heating Equipment
Std 118.2-2006 (RA 2015) Method of Testing for Rating Residential Water Heaters
Std 118.2-2006R SPC 118.2 Method of Testing for Rating Residential Water Heaters
Std 120-2008 Method of Testing to Determine Flow Resistance of HVAC Ducts and Fittings
Std 120-2008R SPC 120 Method of Testing to Determine Flow Resistance of HVAC Ducts and Fittings
Std 124-2007 Methods of Testing for Rating Combination Space-Heating and Water-Heating Appliances
Std 124-2007R SPC 124 Methods of Testing for Rating Combination Space-Heating and Water-Heating Appliances
Std 125-2016   Method of Testing Thermal Energy Meters for Liquid Streams in HVAC Systems
Std 126-2016   Methods of Testing HVAC Air Ducts
Std 127-2012   Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners
Std 127-2012R SPC 127 Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners
Std 128-2011   Method of Rating Portable Air Conditioners
Std 128-2011R SPC 128 Method of Rating Portable Air Conditioners
Std 129-1997 (RA 2002) Measuring Air Change Effectiveness
Std 130-2008 Methods of Testing for Rating Ducted Air Terminal Units
Std 130-2008R SPC 130 Methods of Testing for Rating Ducted Air Terminal Units
Std 133-2015 Method of Testing Direct Evaporative Air Coolers
Std 134-2005 (RA 2014)   Graphic Symbols for Heating, Ventilating, Air Conditioning and Refrigerating Systems
Std 135-2012 SSPC 135 BACnet - A Data Communication Protocol for Building Automation and Control Networks
Std 135.1-2013 SSPC 135 Method of Test for Conformance to BACnet
Std 137-2013   Methods of Testing for Efficiency of Space-Conditioning/Water-Heating Appliances that Include a Desuperheater Water Heater
Std 138-2013   Method of Testing for Rating Ceiling Panels for Sensible Heating and Cooling
Std 139-2015 Method of Testing for Rating Desiccant Dehumidifiers Utilizing Heat for the Regeneration Process
Std 140-2014 SSPC 140 Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs
Std 143-2015 Method of Testing for Rating Indirect Evaporative Coolers
Std 145.1-2105  SSPC 145 Laboratory Method for Assessing the Performance of Gas-Phase Air Cleaning Systems: Loose Granular Media
Std 145.2-2011 SSPC 145 Laboratory Test Method for Assessing the Performance of Gas-Phase Air Cleaning Systems: Air Cleaning Devices
Std 146-2011   Method of Testing and Rating Pool Heaters
Std 146-2011R SPC 146 Method of Testing and Rating Pool Heaters
Std 147-2013 SSPC 147 Reducing the Release of Halogenated Refrigerants from Refrigerating and Air-Conditioning Equipment and Systems
Std 149-2013   Laboratory Methods of Testing Fans Used to Exhaust Smoke in Smoke Management Systems
Std 150-2000 (RA 2014) Method of Testing the Performance of Cool Storage Systems
Std 150-2000R SPC 150 Method of Testing the Performance of Cool Storage Systems
Std 152-2014   Ventilation for Commercial Cooking Operations
 Std 153-2015 SPC 153P Method of Test for Mass Flow Capacity of Four-Way Refrigerant Reversing Valves
Std 154-2016 SSPC 154 Ventilation for Commercial Cooking Operations 
  SPC 155P Method of Testing for Rating Commercial Space Heating Boiler Systems 
Std 158.1-2012   Methods of Testing Capacity of Refrigerant Solenoid Valves
Std 158.1-2012R SPC 158.1 Methods of Testing Capacity of Refrigerant Solenoid Valves
Std 158.2-2011   Methods of Testing Capacity for Refrigerant Pressure Regulators
Std 158.2-2011R SPC 158.2 Methods of Testing Capacity for Refrigerant Pressure Regulators
Std 160-2009 SSPC 160 Criteria for Moisture-Control Design Analysis in Buildings
Std 161-2013 SSPC 161 Air Quality Within Commercial Aircraft
  SPC 164P To develop the 164 series standards. Standards on periodic maintenance.
Std 164.1-2012 (RA 2016)   Method of Test for Residential Central System Humidifiers
Std 164.2-2012 (RA 2016)   Methods of Test for Self-Contained Residential Humidifiers
Std 164.3-2015   Method of Test for Commercial and Industrial Isothermal Humidifiers
Std 169-2013 SSPC 169 Climatic Data for Building Design Standards
Std 170-2013 SSPC 170 Ventilation of Health Care Facilities
Std 171-2008 Method of Test of Seismic Restraint Devices for HVAC&R Equipment
Std 171-2008R SPC 171 Method of Test of Seismic Restraint Devices for HVAC&R Equipment
  SPC 172P Method of Test for Insoluble Materials in Synthetic Lubricants and HFC Refrigerant Systems
Std 173-2012 (RA 2016)   Method of Test to Determine the Performance of Halocarbon Refrigerant Leak Detectors
Std 174-2009 Method of Test for Rating Desiccant-Based Dehumidification Equipment
Std 174-2009R SPC 174 Method of Test for Rating Desiccant-Based Dehumidification Equipment
Std 180-2012   Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems
Std 180-2012R SPC 180 Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems
  SPC 181P Methods of Testing Liquid-to-Liquid Heat Exchangers
Std 182-2008 (RA 2013)   Method of Testing Absorption Water-Chilling and Water-Heating Packages
Std 182-2008R SPC 182 Method of Testing Absorption Water-Chilling and Water-Heating Packages
Std 183-2007 (RA 2014)   Peak Cooling and Heating Load Calculations in Buildings Except Low-Rise Residential Buildings
  SPC 184P Method of Test for Field Test of Liquid-Chilling Systems
 Std 185.1-2015 SSPC 185 Method of Testing UVC Lights for Use in Air Handling Units or Air Ducts to Inactivate Airborne Microorganisms
 Std 185.2-2014 SSPC 185 Method of Testing Ultraviolet Lamps for Use in HVAC&R Units or Air Ducts to Inactivate Microorganisms on Irradiated Surfaces
 Std 188-2015 SSPC 188 Legionellosis: Risk Management for Building Water Systems
Std 189.1-2014 SSPC 189.1 Standard for the Design of High-Performance, Green Buildings Except Low-Rise Residential Buildings
  SPC 189.3P  Design, Construction and Operation of Sustainable High Performance Health Care Facilities
Std 190-2013   Method of Testing for Rating Indoor Pool Dehumidifiers
  SPC 191P  Standard for the Conservation of Water Use in Building, Site and Mechanical Systems 
Std 193-2010 (RA 2014)   Method of Test for Determining the Airtightness of HVAC Equipment
Std 194-2012    Method of Test for Direct-Expansion Ground Source Heat Pumps 
Std 194-2012R SPC 194 Method of Test for Direct-Expansion Ground Source Heat Pumps 
Std 195-2013   Method of Test for Rating Air Terminal Unit Controls
Std 195-2013R SPC 195 Method of Test for Rating Air Terminal Unit Controls
  SPC 196P  Method of Test for Measuring Refrigerant Leak Rates
Std 198-2013   Method of Test for Rating DX-Dedicated Outdoor Air Systems for Moisture Removal Capacity and Moisture Removal Efficiency 
 Std 199-2016   A Method of Test for Rating the Performance of Industrial Pulse Cleaned Dust Collectors 
 Std 200-2015   Method of Testing for Performance Rating of Chilled Beams
Std 200-2015R SPC 200 Method of Testing for Performance Rating of Chilled Beams
 Std 201-2016 SPC 201P Facility Smart Grid Information Model
Std 202-2013 SSPC 202 Commissioning Process for Buildings and Systems
 Std 203-2014 Method of Test for Determining Heat Gain of Office Equipment Used in Buildings
  SPC 204P Method of Test for Rating Micro Combined Heat and Power Devices
  SPC 205P Standard Representation of Performance Simulation Data for HVAC&R and Other Facility Equipment
Std 206-2013   Method of Testing for Rating of Multi-Purpose Heat Pumps for Residential Space Conditioning and Water Heating
  SPC 207P Laboratory Method of Test of Fault Detection and Diagnostics Applied Commercial Air-Cooled Packaged Systems
  PC 208P Method of Test for Determining Hydronic System Balance Valve Capacity
  SPC 209P Energy Simulation Aided Design for Buildings Except Low-Rise Residential Buildings
  SPC 210P Method of Testing for Rating Commercial Walk-in Refrigerators and Freezers
  SPC 211P Standard for Commercial Building Energy Audits
  SPC 212P Method of Test for Determining Energy Performance and Water-Use Efficiency of Add-On Evaporative Pre-Coolers for Unitary Air Conditioning Equipment
  PC 213P Method for Calculating Moist Air Thermodynamic Properties
  SPC 214P Standard for Measuring and Expressing Building Energy Performance in a Rating Program
  SPC 215P Method of Test to Determine Leakage Airflows and Fractional Leakage of Operating Air-Handling Systems
  SPC 216P Methods of Test for Determining Application Data of Overhead Circulator Fans
  SPC 217P Non-Emergency Ventilation in Enclosed Road, Rail and Mass Transit Facilities
  SPC 218P Method of Test for Lubricant and Refrigerant Miscibility Determination
  SPC 219P Method of Testing the Ability of Liquid Line Filter Driers or Adsorbents to Remove Organic and Inorganic Acid
  SPC 220P Method of Testing for Rating Small Commercial Blast Chillers, Chiller-Freezers, and Freezers
  SPC 221P Test Method to Measure and Score the Operating Performance of an Installed Constant Volume Unitary HVAC System