Artificial intelligence (AI) policy: ASHRAE prohibits the entry of content from any ASHRAE publication or related ASHRAE intellectual property (IP) into any AI tool, including but not limited to ChatGPT. Additionally, creating derivative works of ASHRAE IP using AI is also prohibited without express written permission from ASHRAE.

Close
logoShaping Tomorrow's Built Environment Today

Understanding Psychrometrics, Third Edition: Psychrometric Charts

Psychrometric Charts

Systéme International (SI) Psychrometric Charts

ASHRAE
Desig.

Temperature Range

Humidity Ratio
massWV/massDA

Barometric Pressure

Elevation

Pascal

millimetre Hg

metre

SI-1

Normal:
0°C to 50°C

0 to 0.03

101,325

760.0

Sea Level

SI-2

Low:
-40°C to 10°C

0 to 0.05

101,325

760.0

Sea Level

SI-3

High:
10°C to 120°C

0 to 0.09

101,325

760.0

Sea Level

SI-4

Very High:
100°C to 200°C

0 to 0.09

101,325

760.0

Sea Level

SI-5

Normal:
0°C to 50°C

0 to 0.03

92,634

694.8

750

SI-6

Normal:
0°C to 50°C

0 to 0.03

84,556

634.2

1500

SI-7

Normal:
0°C to 50°C

0 to 0.03

77,058

578.0

2250

SI-8

Ultrahigh:
200°C to 320°C

0 to 1.0

101325

760.0

Sea Level

SI-9

Ultrahigh:
200°C to 320°C

0 to 1.0

92634

694.8

750

SI-10

Ultrahigh:
200°C to 320°C

0 to 1.0

84556

634.2

1500

SI-11

Ultrahigh:
200°C to 320°C

0 to 1.0

77058

578.0

2250

SI-12

Ultrahigh:
200°C to 320°C

0 to 1.0

200,000

1500.1

-6123

SI-13

Ultrahigh:
200°C to 320°C

0 to 1.0

500,000

3750.3

-15732

SI-14

Ultrahigh:
200°C to 320°C

0 to 1.0

1,000,000

7500.6

-24199

SI-15

Ultrahigh:
200°C to 320°C

0 to 1.0

2,000,000

15001.2

-33860

SI-16

Ultrahigh:
200°C to 320°C

0 to 1.0

5,000,000

37503.1

-48752

*SI-17

Full Range
0°C to 400°C

0 to 1.0

5529.3

41.47

20,000

*SI-18

Full Range
0°C to 400°C

0 to 1.0

101,325

760.0

Sea Level

*SI-19

Full Range
0°C to 400°C

0 to 1.0

2,000,000

15001.2

-33860

* Prepared by University of Missouri-Rolla (August 2000)


Inch-Pound (I-P) Psychrometric Charts

ASHRAE
Desig.

Temperature Range

Humidity Ratio
massWV/massDA

Barometric Pressure

Elevation

Pascal

inches Hg

feet

IP-1

Normal:
32°F to 120°F

0 to 0.03

101325

29.9213

Sea Level

IP-2

Low:
-40°F to 50°F

0 to 0.005

101325

29.9213

Sea Level

IP-3

High:
60°F to 250°F

0 to 0.09

101325

29.9213

Sea Level

IP-4

Normal:
32°F to 120°F

0 to 0.03

84307

24.8959

5000

IP-5

Normal:
32°F to 120°F

0 to 0.03

76712

22.6532

7500

IP-6

Ultrahigh:
400°F to 600°F

0 to 1.0

101325

29.9213

Sea Level

IP-7

Ultrahigh:
400°F to 600°F

0 to 1.0

92500

27.3152

2500

IP-8

Ultrahigh:
400°F to 600°F

0 to 1.0

84307

24.8959

5000

IP-9

Ultrahigh:
400°F to 600°F

0 to 1.0

76712

22.6532

7500

Note: These SI and I-P charts are based on the dry-air component of the moist-air mixture having a composition as described in the pertinent underlying research. (The relative molecular mass of dry air is 28.9645 kg/kmol except for charts SI-8 through SI-19, for which the molecular mass of dry air is 28.95849 kg/kmol.)

Close