Indoor air quality (IAQ) is one of the most commonly discussed aspect of building indoor environmental quality (IEQ). IAQ has direct effects on our health as well as the perception of an acceptable indoor environment. In the United States, ASHRAE Standard 62.1: Ventilation for Acceptable Indoor Air Quality is the most commonly referenced standard to quantify acceptable conditions and appropriate HVAC system design. The standard either forms the basis for most mechanical codes or is directly referenced by the codes themselves.
ASHRAE offers a customized training solution for Middle East practitioners that outlines the minimum acceptable requirements for buildings IAQ. The course focuses on the basic requirements of ASHRAE Standard 62.1
This course provides an overview of the requirements of the standard with emphasis on changes from the previous versions. Updates to the indoor air quality procedure for determining minimum ventilation rates are discussed.
BONUS! 30% Discount on Standard 62.1-2025 -- Ventilation and Acceptable Indoor Air Quality (ANSI Approved). (Soft Copies). Click on register now to avail the offer.
Course Objectives:
- Review requirements of ASHRAE Standard 62.1
- Perform psychrometric calculation of the resultant dew point to check compliance with the standard maximum dew point requirement
- Clarify how different approaches to HVAC design result in different quantities of outside air at the outside air intake
- Review single zone, 100% outdoor air, and multiple zone constant volume (CV) systems
- As an exercise, apply requirements to a hypothetical new building—Office Building in Dubai, UAE
- Compare the ventilation rate procedure, the indoor air quality procedure, and the natural ventilation procedure
Agenda
6 Professional Development Hours (PDH)
3:00 – 6:00 PM UAE Time each day
Part 1: Wed, 8 Apr 2026
- Introduction and Course Objectives
- What’s in Air
- Background of ASHRAE Standard 62.1
- Standard 62.1 Definitions
- Air Quality:
- Air Classification and Recirculation
- Maximum Indoor dew point exercise
Part 2: Thurs, 9 Apr 2026
- Ventilation Rate Procedure
- 100% Outdoor Air Systems Multiple Zone Recirculating Systems:
- Demand Control Ventilation
- Indoor Air Quality Procedure:
- Beyond the VRP
- Natural Ventilation Procedure
- Course Summary
Instructor
Hassan Younes, Member ASHRAE, CHD, BEAP, BEMP, HFDP
Fees
Includes course admittance, course materials and Certificate of Attendance.
$343 ($263 ASHRAE Member)
Developing economy fees available. Click on register now to view or contact globaltraining@ashrae.org
Group Discount Fee: Enroll 3 or more participants at the same time and save. Email globaltraining@ashrae.org for group registration assistance.
BONUS! 30% Discount on Standard 62.1-2025 -- Ventilation and Acceptable Indoor Air Quality (ANSI Approved). (Soft Copies). Click on register now to avail the offer.
Cancellation Policy: Registration fees will be refunded in full if cancellation is received by ASHRAE Global Training at least 15 working days prior to the training date at globaltraining@ashrae.org . Cancellations received between 15 and 10 working days before the course date are subject to a $50 cancellation fee. Registrants who do not attend a course or cancel less than 10 working days before the course date are liable for the entire course registration fee.
A substitute registrant may be enrolled at any time by contacting globaltraining@ashrae.org. Member/Non-Member rates will apply to the substitute registrant.
To return to the full list of ASHRAE Global Training's scheduled courses, click here.