IDENTIFIER
|
TC/TG
|
COST
|
RESEARCH TITLE OR SUBJECT
|
CONTRACTOR
|
NOTES
|
|
|
1696-RP
|
4.04
|
197,075
|
Thermal, Moisture and Air Transport Property Values for New Building and Insulating Materials
|
BUILDING SCIENCE CONSULTING, INC. Waterloo, Ontario, Canada
|
Active
|
|
|
1780-RP
|
9.10 2.03 SSPC 62.1
|
186,892
|
Test Method to Evaluate Cross-Contamination of Gaseous Contaminant within Total Energy Recovery Wheels
|
UNIVERSITY OF SASKATCHEWAN CAREY SIMONSON (11)
|
NEW
|
|
|
1847-RP
|
4.02
|
144,000
|
Updating Climatic Design Information for the 2021 ASHRAE Handbook, Standard 169, and the Handbook of Smoke Control Engineering.
|
KLIMAAT CONSULTING & INNOVATION INC. - Ontario, Canada
|
Active
|
|
|
1852-RP
|
2.06
|
144,645
|
Develop Performance Metric, Criteria, and Process to Measure and Predict Speech Privacy in High Performance Buildings
|
SOFT Db Acoustical Accounting - Roderick Mackenzie - Mont-Royal (Quebec)
|
NEW
|
|
|
GIA 18-19
|
7.05
|
10,000
|
Determining the potential for electrical load shifting and energy conservation through the use of smart thermostats in multi-unit residential buildings
|
U-TORONTO - Helen Stopps
|
Graduate Student Grant-in-Aid
|
|
GIA 18-19
|
1.04
|
10,000
|
Model predictive control strategies of large-scale HVAC&R system for the optimization of the energy savings and occupants thermal comfort.
|
U-LAVAL - Louis-Gabriel Maltais
|
Graduate Student Grant-in-Aid
|
|
GIA 18-19
|
4.07
|
10,000
|
Systematic building portfolio energy modelling simplification and energy reduction
|
CARLETON U - Hailey Fernald
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
7.05
|
10,000
|
Smart Operation and control of Offcies to Improve Comfort and Energy Performance
|
CARLETON U - Jayson Bursill
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
1.04
|
10,000
|
Development of a comprehensive methodology to streamline the implementation of model predictive control (MPC) strategies in buildings to improve their energy performance
|
CONCORDIA U - Ali Saberi Derakhtenjani
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
8.03
|
10,000
|
Energy Modeling and Field Testing of Residential Gas-Fired Absorption Heat Pump System in Canadian Cold Climate
|
RYERSON U - Kajen Ethirveerasingham
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
2.03
|
10,000
|
Hierarchically Meso-/Macro porous Titanium Dioxide Embedded in Carbonaceous Materials for Photocatalytic Degradation of Air Pollutants
|
CONCORDIA U - Alireza Haghighatmamaghani
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
2.08
|
10,000
|
Evaluating the impacts of energy retrofits on Indoor Environmental Quality in Toronto social housing units
|
U-TORONTO - Ernesto Patnio
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
RBC
|
10,000
|
Evaluation of the energy performance and the thermal comfort of wood residential buildings
|
U-LAVAL - Jean Rouleau
|
Graduate Student Grant-in-Aid
|
|
GIA 17-18
|
7.05
|
10,000
|
Building Operation Specialist – a Distributed Real-time Building Fault Detection and Diagnostics System with Performance Evaluation
|
CARLETON U - Zixiao Shi
|
Graduate Student Grant-in-Aid
|
|
NIA 18-19
|
RBC
|
125,000
|
Inter-suite Air Transfer in Multi-Family Buildings: Characterization and Development of New Field Testing Protocols
|
U. TORONTO - Marianne Touchie
|
New Investigator award
|