Number
|
Chemical Name
|
Chemical Formula
|
|
Methane Series
|
11 |
trichlorofluoromethane |
CCl 3F |
12 |
dichlorodifluoromethane |
CCl 2F 2 |
12B1 |
bromochlorodifluoromethane |
CBrClF 2 |
13 |
chlorotrifluoromethane |
CClF 3 |
13B1 |
bromotrifluoromethane |
CBrF 3 |
13I1 |
trifluoroiodomethane |
CF3 I |
14e |
tetrafluoromethane (carbon tetrafluoride) |
CF 4 |
21 |
dichlorofluoromethane |
CHCl 2F |
22 |
chlorodifluoromethane |
CHClF 2 |
23 |
trifluoromethane |
CHF 3 |
30 |
dichloromethane (methylene chloride) |
CH 2Cl 2 |
31 |
chlorofluoromethane |
CH 2ClF |
32 |
difluoromethane (methylene fluoride) |
CH 2F 2 |
40 |
chloromethane (methyl chloride) |
CH 3Cl |
41 |
fluoromethane (methyl fluoride) |
CH 3F |
50 |
methane |
CH 4 |
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Ethane Series
|
113 |
1,1,2-trichloro-1,2,2-trifluoroethane |
CCl 2FCClF 2 |
114 |
1,2-dichloro-1,1,2,2-tetrafluoromethane |
CClF 2CClF 2 |
115 |
chloropentafluoroethane |
CClF 2CF 3 |
116 |
hexafluoroethane |
CF 3CF 3 |
123 |
2,2-dichloro-1,1,1-trifluoroethane |
CHCl 2CF 3 |
124 |
2-chloro-1,1,1,2-tetrafluoroethane |
CHClFCF 3 |
125 |
pentafluoroethane |
CHF 2CF 3 |
134a |
1,1,1,2-tetrafluoroethane |
CH 2FCF 3 |
141b |
1,1-dichloro-1-fluoroethane |
CH 3CCl 2F |
142b |
1-chloro-1,1-difluoroethane |
CH 3CClF 2 |
143a |
1,1,1-trifluoroethane |
CH 3CF 3 |
152a |
1,1-difluoroethane |
CH 3CHF 2 |
170 |
ethane |
CH 3CH 3 |
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Ethers
|
E170 |
Methoxymethane (dimethyl ether) |
CH3OCH3 |
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Propane
|
218 |
octafluoropropane |
CF 3CF 2CF 3 |
227ea |
1,1,1,2,3,3,3-heptafluoropropane |
CF 3CHFCF 3 |
236fa |
1,1,1,3,3,3-hexafluoropropane |
CF 3CH 2CF 3 |
245fa |
1,1,1,3,3-pentafluoropropane |
CHF 2CH 2CF 3 |
290 |
propane |
CH 3CH 2CH 3 |
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Cyclic Organic Compounds
|
C318 |
octafluorocyclobutane |
-(CF 2) 4- |
|
Miscellaneous Organic Compounds |
Number
|
Chemical Name
|
Chemical Formula
|
hydrocarbons
|
600 |
butane |
CH 3CH 2CH 2CH 3 A3 |
600a |
2-methylpropane (isobutane) |
CH(CH 3) 2CH 3 A3 |
601 |
pentane |
CH 3CH 2CH 2 CH 2CH 3 |
601a |
2-methylbutane (isopentane) |
CH(CH 3) 2 CH 2CH 3 |
oxygen compounds |
610 |
ethoxyethane (ethyl ether) |
CH 3CH 2 OCH 2CH 3 |
611 |
methyl formate |
HCOOCH 3 |
sulfur compounds |
620 |
(Reserved for future assignment) |
|
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Nitrogen Compounds
|
630 |
methanamine (methyl amine) |
CH 3NH 2 |
631 |
ethanamine (ethyl amine) |
CH 3CH 2(NH 2) |
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Inorganic Compounds
|
702 |
hydrogen |
H 2 |
704 |
helium |
He |
717 |
ammonia |
NH 3 |
718 |
water |
H 2O |
720 |
neon |
Ne |
728 |
nitrogen |
N 2 |
732 |
oxygen |
O 2 |
740 |
argon |
Ar |
744 |
carbon dioxide |
CO 2 |
744A |
nitrous oxide |
N 2O |
764 |
sulfur dioxide |
SO 2 |
|
Number
|
Chemical Name
|
Chemical Formula
|
|
Unsaturated Organic Compounds
|
1130(E) |
trans-1,2-dichloroethene |
CHCl=CHCl |
R-1132a |
1,1-difluoroethylene |
CF2=CH2 |
1150 |
ethene (ethylene) |
CH2=CH2 |
R-1224yd(Z) |
(Z)-1-chloro-2,3,3,3-tetrafluoropropene |
CF3CF=CHCl |
1233zd(E) |
trans-1-chloro-3,3,3-trifluoro-1-propene |
CF3CH=CHCl |
1234yf |
2,3,3,3-tetrafluoro-1-propene |
CF3CF=CH2 |
1234ze(E) |
trans-1,3,3,3-tetrafluoro-1-propene |
CF3CH=CHF |
1270 |
propene (propylene) |
CH3CH=CH 2 |
1336mzz(E) |
trans-1,1,1,4,4,4-hexafluoro-2-butene |
CF3CH=CHCF3 |
1336mzz(Z) |
cis-1,1,1,4,4,4-hexaflouro-2-butene |
CF3CHCHCF3 |
Refrigerant Blends
|
Number
|
Refrigerant Composition (Mass % )
|
|
Zeotropes
|
400 |
R-12/114 (must be specified) (50.0/50.0) (60.0/40.0) |
|
401A |
R-22/152a/124 (53.0/13.0/34.0) |
|
401B |
R-22/152a/124 (61.0/11.0/28.0 |
|
401C |
R-22/152a/124 (33.0/15.0/52.0) |
|
402A |
R-125/290/22 (60.0/2.0/38.0) |
|
402B |
R-125/290/22 (38.0/2.0/60.0) |
|
403A |
R-290/22/218 (5.0/75.0/20.0) |
|
403B |
R-290/22/218 (5.0/56.0/39.0) |
|
404A |
R-125/143a/134a (44.0/52.0/4.0) |
|
405A |
R-22/152a/142b/C318 (45.0/7.0/5.5/42.5) |
|
406A |
R-22/600a/142b (55.0/4.0/41.0) |
|
407A |
R-32/125/134a (20.0/40.0/40.0) |
|
407B |
R-32/125/134a (10.0/70.0/20.0) |
|
407C |
R-32/125/134a (23.0/25.0/52.0) |
|
407D |
R-32/125/134a (15.0/15.0/70.0) |
|
407E |
R-32/125/134a (25.0/15.0/60.0) |
|
407F |
R-32/125/134a (30.0/30.0/40.0) |
|
407G |
R-32/125/134a (2.5/2.5/95.0) |
|
407H |
R-32/125/134a (32.5/15.0/52.5) |
|
407I |
R-32/125/134a (19.5/8.5/72.0) |
|
408A |
R-125/143a/22 (7.0/46.0/47.0) |
|
409A |
R-22/124/142b (60.0/25.0/15.0) |
|
409B |
R-22/124/142b (65.0/25.0/10.0) |
|
410A |
R-32/125 (50.0/50.0) |
|
410B |
R-32/125 (45.0/55.0) |
|
411A |
R-1270/22/152a) (1.5/87.5/11.0) |
|
411B |
R-1270/22/152a (3.0/94.0/3.0) |
|
412A |
R-22/218/143b (70.0/5.0/25.0 k |
|
413A |
R-218/134a/600a (9.0/88.0/3.0) |
|
414A |
R-22/124/600a/142b (51.0/28.5/4.0/16.5) |
|
414B |
R-22/124/600a/142b (50.0/39.0/1.5/9.5) |
|
415A |
R-22/152a (82.0/18.0) |
|
415B |
R-22/152a (25.0/75.0) |
|
416A |
R-134a/124/600 (59.0/39.5/1.5) |
|
417A |
R-125/134a/600 (46.6/50.0/3.4) |
|
417B |
R-125/134a/600 (79.0/18.3/2.7) |
|
417C |
R-125/134a/600 (19.5/78.8/1.7) |
|
418A |
R-290/22/152a (1.5/96.0/2.5) |
|
419A |
R-125/134a/E170 (77.0/19.0/4.0) |
|
419B |
R-125/134a/E170 (48.5/48.0/3.5) |
|
420A |
R-134a/142b (88.0/12.0) |
|
421A |
R-125/134a (58.0/42.0) |
|
421B |
R-125/134a (85.0/15.0) |
|
422A |
R-125/134a/600a (85.1/11.5/3.4) |
|
422B |
R-125/134a/600a (55.0/42.0/3.0) |
|
422C |
R-125/134a/600a (82.0/15.0/3.0) |
|
422D |
R-125/134a/600a (65.1/31.5/3.4) |
|
422E |
R-125/134a/600a (58.0/39.3/2.7) |
|
423A |
134a/227ea (52.5/47.5) |
|
424A |
R-125/134a/600a/600/601a (50.5/47.0/0.9/1.0/0.6) |
|
425A |
R-32/134a/227ea (18.5/69.5/12) |
|
426A |
R-125/134a/600/601a (5.1/93.0/1.3/0.6) |
|
427A |
R-32/125/143a/134a (15.0/25.0/10.0/50.0) |
|
427C |
R-32/125/143a/134a (25.0/25.0/10.0/40.0) |
|
428A |
R-125/143a/290/600a (77.5/20.0/0.6/1.9) |
|
429A |
R-E170/152a/600a (60.0/10.0/30.0) |
|
430A |
R-152a/600a (76.0/24.0) |
|
431A |
R-290/152a (71.0/29.0) |
|
432A |
R-1270/E170 (80.0/20.0) |
|
433A |
R-1270/290 (30.0/70.0) |
|
433B |
R-1270/290 (5.0/95.0) |
|
433C |
R-1270/290 (25.0/75.0) |
|
434A |
R-125/143a/134a/600a (63.2/18.0/16.0/2.8) |
|
435A |
R-E170/152a (80.0/20.0) |
|
436A |
R-290/600a (56.0/44.0) |
|
436B |
R-290/600a (52.0/48.0) |
|
436C |
R-290/600a (95.0/5.0) |
|
437A |
R-125/134a/600/601 (19.5/78.5/1.4/0.6) |
|
438A |
R-32/125/134a/600/601a (8.5/45.0/44.2/1.7/0.6) |
|
439A |
R-32/125/600a (50.0/47.0/3.0) |
|
440A |
R-290/134a/152a (0.6/1.6/97.8) |
|
441A |
R-170/290/600a/600 (3.1/54.8/6.0/36.1) |
|
442A |
R-32/125/134a/152a/227ea (31.0/31.0/30.0/3.0/5.0) |
|
443A |
R-1270/290/600a (55.0/40.0/5.0) |
|
444A |
R-32/152a/1234ze(E) (12.0/5.0/83.0) |
|
444B |
R-32/152a/1234ze(E) (41.5/10.0/48.5) |
|
445A |
R-744/134a/1234ze(E) (6.0/9.0/85.0) |
|
446A |
R-32/1234ze(E)/600 (68.0/29.0/3.0) |
|
447A |
R-32/125/1234ze(E) (68.0/3.5/28.5) |
|
447B |
R-32/125/1234ze (E) (68.0/8.0/24.0) |
|
448A |
R-32/125/1234yf/134a/1234ze(E) (26.0/26.0/20.0/21.0/7.0) |
|
448B |
R-32/125/1234yf/134a/1234ze(E) (21.0/21.0/20.0/31.0/7.0) |
|
449A |
R-32 /125 /1234yf /134a (24.3/24.7/25.3/25.7) |
|
449B |
R-32/125/1234yf/134a (25.2/24.3/23.2/27.3) |
|
449C |
R-32/125/1234yf/134a (20.0/20.0/31.0/29.0) |
|
450A |
R-134a/1234ze(E) (42.0/58.0) |
|
451A |
R-1234yf/134a (89.8/10.2) |
|
451B |
R-1234yf/134a (88.8/11.2) |
|
452A |
R-32/125/1234yf (11.0/59.0/30.0) |
|
452B |
R-32/125/1234yf (67.0/7.0/26.0) |
|
452C |
R-32/125/1234yf (12.5/61.0/26.5) |
|
453A |
R-32/125/134a/227ea/600/601a (20.0/20.0/53.8/5.0/0.6/0.6) |
|
454A |
R-32/1234yf (35.0/65.0) |
|
454B |
R-32/1234yf (68.9/31.1) |
|
454C |
R-32/1234yf (21.5/78.5) |
|
455A |
R-744/32/1234yf (3.0/21.5/75.5) |
|
456A |
R-32/134a/1234ze(E) (6.0/45.0/49.0) |
|
457A |
R-32/1234yf/152a (18.0/70.0/12.0) |
|
457B |
R-32/1234yf/152a (35.0/55.0/10.0) |
|
458A |
R-32/125/134a/227ea/236fa (20.5/4.0/61.4/13.5/0.6) |
|
459A |
R-32/1234yf/1234ze(E) (68.0/26.0/6.0) |
|
459B |
LTR 11: R-32/1234yf/1234ze(E) (21.0/69.0/10.0) |
|
460A |
LTR 10: R-32/125/134a/1234ze(E) (12.0/52.0/14.0/22.0) |
|
460B |
LTR4X10: R-32/125/134a/1234ze(E) (28.0/25.0/20.0/27.0) |
|
460C |
R-32/125/134a/1234ze(E) (2.5/2.5/46.0/49.0) |
|
461A |
R-125/143a/134a/227ea/600a (55.0/5.0/32.0/5.0/3.0) |
|
462A |
R-32/125/143a/134a/600 (9.0/42.0/2.0/44.0/3.0) |
|
463A |
R-744/32/125/1234yf/134a (6.0/36.0/30.0/14.0/14.0) |
|
464A |
R-32/125/1234ze(E)/227ea (27.0/27.0/40.0/6.0) |
|
465A |
R-32/290/1234yf (21.0/7.9/71.1) |
|
466A |
R-32/125/131I (49.0/11.5/39.5) |
|
467A |
R-32/125/134a/600a (22.0/5.0/72.4/0.6) |
|
468A |
R-1132a/32/1234yf (3.5/21.5/75.0) |
|
469A |
R-744/32/125 (35.0/32.5/32.5) |
|
470A |
R-744/32/125/134a/1234ze(E)/227ea (10.0/17.0/19.0/7.0/44.0/3.0) |
|
470B |
R-744/32/125/134a/1234ze(E)/227ea (10.0/11.5/11.5/3.0/57.0/7.0) |
|
471A |
R-1234ze(E)/227ea/1336mzz(E) (78.7/4.3/17.0) |
|
472A |
R-744/32/134a (69.0/12.0/19.0) |
|
473A |
R-1132a/23/744/125 (20.0/10.0/60.0/10.0) |
|
|
Refrigerant Composition (Mass % )
|
Number
|
Azeotropes
|
500 |
R-12/152a (73.8/26.2) |
|
501 |
R-22/12 (75.0/25.0) |
|
502 |
R-22/115 (48.8/51.2) |
|
503 |
R-23/13 (40.1/59.9) |
|
504 |
R-32/115 (48.2/51.8) |
|
505 |
R-12/31 (78.0/22.0) |
|
506 |
R-31/114 (55.1/44.9) |
|
507A |
R-125/143a (50.0/50.0) |
|
508A |
R-23/116 (39.0/61.0) |
|
508B |
R-23/116 (46.0/54.0) |
|
509A |
R-22/218 (44.0/56.0) |
|
510A |
R-E170/600a (88.0/12.0) |
|
511A |
R-290/E170 (95.0/5.0) |
|
512A |
R-134a/152a (5.0/95.0) |
|
513A |
R-1234yf/134a (56.0/44.0) |
|
513B |
R-1234yf/134a (58.5/41.5) |
|
514A |
R-1336mzz(Z)/1130(E) (74.7/25.3) |
|
515A |
R-1234ze (E)/227ea (88.0/12.0) |
|
515B |
R-1234ze(E)/227ea (91.1/8.9) |
|
516A |
R-1234yf/134a/152a (77.5/8.5/14.0) |
|