Supplemental files for ASHRAE Laboratory Design Guide, Second Edition

Share This

Supplemental files for ASHRAE Laboratory Design Guide, Second Edition

Thank you for purchasing ASHRAE Laboratory Design Guide: Planning and Operation of Laboratory HVAC Systems, Second Edition. The files listed below are available only to purchasers of this book; the files can be downloaded to your computer for personal use only. Note that the files included here may be revised from time to time, so users should check here for the most up-to-date versions. When a file is revised, it will be posted to www.ashrae.org/LabDG with a new date at the end of the file name; this revised file will replace any versions previously available on the website. If the files at these links are not accessible, please contact the publisher.

page-excel-icon.gif Laboratory Sustainability Checklist.xlsx (helps designers review potential opportunities to include in the building design for enhancing the sustainability of a laboratory)

page-excel-icon.gif Lab Room Schedule - Sample.xls (allows engineers to schedule pertinent data for all room airflow control devices in one schedule along with room offset, minimum ventilation rate, and maximum cooling demand quantities)

DilutionCalc (.msi file) (calculates downwind dilutions/concentrations from an exhaust stack using the equations from Chapter 45 of ASHRAE Handbook—HVAC Applications)

 Induced Flow Fan Testing.mp4 (119 MB) (shows operation of dilution fans as well as AMCA test methodology used to test and certify fan inlet airflows and total discharge airflows)

 Fan Flow.avi  (shows how air flows from the building and mixes with outdoor air as it flows through an in-line mixed-flow induced draft dilution fan; courtesy of Strobic Air Corporation)

 Plume Caught in Upwind Taller Building’s Wake.avi (flow visualization)

 Plume Impacting Downwind Taller Building.avi (flow visualization)

pdf_icon.png  Room Data Sheets.pdf (examples showing how to gather the technical requirements of each space)

 SEMCO_Heat_Wheel_Purge.exe (shows the principle of the purge in a sensible heat wheel; courtesy of SEMCO)

ASHRAE Journal articles:

pdf_icon.png Room Pressure for Critical Environments by Brian Wiseman, ASHRAE Journal 45(2), 2003

pdf_icon.png HVAC Design in Animal Facilities by Christopher K. Wilkins and Brian A. Waters, ASHRAE Journal 46(9), 2004

pdf_icon.png 2010 ASHRAE Technology Awards: Fume Hood Retrofit by Molly McGuire and Mark Hydeman, ASHRAE Journal 52(9), 2010

pdf_icon.png Technology Award: Cutting-Edge Renovation by Laurier Nichols, Marc-Olivier Lacoursiere, and Mathieu Courchesne, ASHRAE Journal 55(8), 2013

pdf_icon.png ASHRAE Technology Award: Crime Lab Deconstruction by David Shumway, ASHRAE Journal 56(4), 2014

ASHRAE Transactions papers:

pdf_icon.png Cleanroom Pressurization Strategy Update-Quantification and Validation of Minimum Pressure Differentials for Basic Configurations and Applications (Part 1) (RP-1344) by Wei Sun, Keith Flyzik, and John Mitchell, ASHRAE Transactions 119(1), 2013

pdf_icon.png Cleanroom Pressurization Strategy Update-Quantification and Validation of Minimum Pressure Differentials for Basic Configurations and Applications (Part 2) (RP-1344) by Wei Sun, Keith Flyzik, and John Mitchell, ASHRAE Transactions 119(1), 2013

pdf_icon.png Toward Net-Zero Energy Labs in Northern Climate- Montreal Examples by Roland Charneux, ASHRAE Transactions 118(1), 2012

Control of Space Pressurization for Sealed or Tight Rooms by James Coogan, ASHRAE Transactions 118(1), 2012

Seminars presented at ASHRAE Conferences:

2015 ASHRAE Annual Conference, Seminar 11 - Upgrading Ventilation in Existing Laboratories
http://ashraem.confex.com/ashraem/sessiontechprogram.cgi?username=16454&password=772065&wrfredirect=0

2015 ASHRAE Annual Conference, Seminar 12 - Biocontainment Facility Design, Commissioning and Certification Strategies
http://ashraem.confex.com/ashraem/sessiontechprogram.cgi?username=16782&password=622811&wrfredirect=0

2015 ASHRAE Annual Conference, Seminar 40 - Energy Efficient Labs: Case Studies
http://ashraem.confex.com/ashraem/sessiontechprogram.cgi?username=16918&password=502420&wrfredirect=0